DS-CLAMP-15AC

Type
Iron-Core-Clamp
Current Range
15A ACrms
Sensitivity
100mV/A
Accuracy (+25°C)
< 1A: ±2.5% of reading 1-15A: ±1% of reading
of reading 1-12A ±0.5% of reading
Phase Error
< 1A: ±5° of reading 1-15A: ±3° of reading
Bandwidth
2Hz to 10kHz
Resolution
0.01A
TEDS
Fully supported
Overload Capability
1.3 x I nominal
Conductor Position Sensitivity
≤ 0.5% of reading
Influence of Crest Factor
≤ 3 %
Error due Earth Magnetic Field
≤ 15mA/A @ 50Hz
Temp. Coefficient
≤ 0.2% / 10°C
Influence of Frequency
< 5 % of output signal from 20 Hz …1 kHz < 10 %
of output signal from 1 kHz …10 kHz

Connection

General

Dimensions [mm]
135 x 51 x 30
Diameter Conductor
20mm
Coil Diameter
100mm
Operating Temp.
-40°C to +70°C
Operating Humidity
up to 85% (not condensing)
Safety Standards
EN61010-2-032:2012
EMC Standards
EN61326-1:2013
Safety
CAT III 600V CAT IV 300V