IN 1000-S
| Primary Current Range DC, RMS Sinus | 1000 A | 
| Conversation ratio  | 1:1500 | 
| Overload Ability Short Time (100ms)  | 5000 Apk | 
| Max. burden resistor (100 % of lp)  | 4 Ω | 
| di/dt (accurately followed)  | > 100A/µs | 
| Temperature influence  | < 0.3 ppm/K | 
| Output Ratio  | 666 mA @ 1000A | 
| Bandwidth (0.5% of lp) | DC…440kHz | 
| Linearity | <0.003 % | 
| Offset | <0.012 % | 
| Frequency Influence | 0.1 %/kHz | 
| Angular Accuracy | <0.01°+0.05°/k Hz | 
| Rated isolation voltage rms, single isolation CAT III, | 1000 V | 
| 2 IEC 61010-1 standards EN 50178 standards polution deg. | – | 
| Test voltage 50/60 Hz, 1 min  | 4.2kV | 
| Inner diameter  | 38mm | 
| Dimension | 128x106x54 | 
| Supply voltage (± 5%)  | ±15V | 
| Operating humidity  | 20% to 80% (not condensing) | 
| Operating temperature  | +10°C to +50°C | 
| DEWESoft® Shunt  | 1 Ω | 
 
	 
	